Good afternoon,
I have an 09 Granturismo and I’m wondering if anyone here has any ideas on something I have going on. The air con was throwing a code for the air condenser internal fault and I tried, as recommended on here, replacing the pressotat first. At this point, the a/c was working but was trying to get rid of the code. After installation, the code for the condenser is gone but I get a slew of other codes including B1912 “Keyboard Control plate communication error”, which I believe may be the source of all the others, essentially stating there’s no communication with any of the actuators for example “max cold position, LH central vent” etc. The ac cuts off and on at will always going back to 72 degrees, at times the switch back to off is quite violent and it momentarily lights up the dash with a bunch of warnings, then settle out a second later. I’ve tried replacing that fuse for the ac control panel to no avail, tried also recharging the ac and that didn’t help any.
I’ve seen the 99 issue in here but doesn’t seem any had it to where the error was intermittent. Any of the mechanics in here ever saw this before? Is there anything I could do before finding a shop? I’m thinking having someone check the wiring for the ac control unit or check to see if that new pressostat may be causing the issue.
Thanks
I have an 09 Granturismo and I’m wondering if anyone here has any ideas on something I have going on. The air con was throwing a code for the air condenser internal fault and I tried, as recommended on here, replacing the pressotat first. At this point, the a/c was working but was trying to get rid of the code. After installation, the code for the condenser is gone but I get a slew of other codes including B1912 “Keyboard Control plate communication error”, which I believe may be the source of all the others, essentially stating there’s no communication with any of the actuators for example “max cold position, LH central vent” etc. The ac cuts off and on at will always going back to 72 degrees, at times the switch back to off is quite violent and it momentarily lights up the dash with a bunch of warnings, then settle out a second later. I’ve tried replacing that fuse for the ac control panel to no avail, tried also recharging the ac and that didn’t help any.
I’ve seen the 99 issue in here but doesn’t seem any had it to where the error was intermittent. Any of the mechanics in here ever saw this before? Is there anything I could do before finding a shop? I’m thinking having someone check the wiring for the ac control unit or check to see if that new pressostat may be causing the issue.
Thanks